Answers are grounded in this paper and cite their sources.
The structural integrity of concrete cast in place drilled foundations is often determined by cross hole sonic logging, low strain impact-echo, gamma-gamma logging, or thermal integrity methods. Studies have characterized the frequency of observed significant anomalies detected by the first three methods. This study reviews a large database of drilled foundations tested by thermal methods over the last seven years. The frequency and general location in the shaft of major anomalies, as characterized by a 6% effective radius reduction criteria, are summarized and reviewed. Based on these criteria, anomalies occur in approximately 15% of the 2104 shafts reported. Of those 318 drilled foundations with anomalies, 77 (28%) identified anomalies occur within a length equivalent to the bottom two diameters of the foundation element, a rate similar to that reported by studies using other integrity methods.
No takes yet. Share an insight, caveat, or question.
B.A. Robinson (2024) studied this question.