Objective: This study aims to assess the impact of bioceramic and resin based sealers on postendodontic pain after endodontic treatment performed in single visit. Methods: In this study, forty patients in need of endodontic therapy were chosen. single visit endodontic treatment was done for the patients but obturated using two different types of sealers: in Group 1: AH Plus sealer was used and in Group 2: EndoSequence BC sealer Hiflow was used. Post endodontic pain was measured for 12,24,48 and 72 hours postoperatively. Results: Both sealer groups’ post-endodontic pain levels did not significantly differ from one another. Conclusions: Both AH Plus and Endosequence BC sealer Hiflow perform similarly in terms of the incidence and severity of postoperative pain in teeth with symptomatic irreversible pulpitis (SIP). Endodontics performed in a single visit can utilise any type of both sealers without worrying about pain following obturation.
No takes yet. Share an insight, caveat, or question.
AMIN et al. (2024) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: