Fully electric propulsion systems integrating hydrogen-powered fuel cells and batteries are promising options to reduce the overall climate impact of regional aircraft. However, the increase in low-temperature heat sources aboard the aircraft calls for advanced thermal management system solutions. To address this challenge, this study presents a sizing methodology for ram air heat exchangers in the nacelle-integrated cooling loop of an all-electric regional aircraft based on the ATR-72 platform. Different discretization schemes are compared to identify an optimal sizing method. The results highlight the simplicity and efficiency of the 0D ε -NTU model. Geometric design variables are optimized with respect to drag and mass during a hot-day take-off. The resulting Pareto front reveals a tendency for low airflow outlet temperatures and large diffuser area ratios to result in lightweight designs but in turn, induce high drag and require a large installation space. Comparative analyses of specific optimal ram air duct designs and equivalent skin heat exchangers demonstrate the potential of a second heat sink over a flight mission. The limited heat transfer area of the skin heat exchanger proves insufficient for hot-day take-off and climb but offers advantages during cruise and descent thanks to the reduced drag.
No takes yet. Share an insight, caveat, or question.
Nozinski et al. (2024) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: