The piezocone penetration test (CPTU) is an efficient in-situ testing method for delineating subsurface stratigraphy and interpreting geoparameters continuously with depth. However, owing to the regional sensitivity and geological diversity, the applicability of CPTU-based geotechnical parameter evaluation methods is limited when applied to specific sites. This requires further scrutiny considering the different geological histories and local soil conditions. In this study, a database that included a collection of CPTU test sites in Jiangsu Province, China, was compiled containing high-quality sampling and laboratory testing performed to characterize the permeability of clay soils. Several published CPTU correlations for determining soil permeability were summarized and compared with laboratory-measured soil permeability as a benchmark reference. The evaluation results indicated that the I c -based correlations can provide a reasonably good determination of the permeability for the investigated soils with root mean squared error of 0.89 and mean absolute error of 0.77. Finally, a modified approach was presented to evaluate the permeability coefficient of Jiangsu clay soils, which was calibrated using two additional case studies.
No takes yet. Share an insight, caveat, or question.
Feng et al. (2024) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: