Answers are grounded in this paper and cite their sources.
Introduction the management of patients with recent-onset atrial fibrillation (AF) is to achieve sinus rhythm (SR) by electrical or pharmacological cardioversion (CV). However, frequently SR is spontaneously restored, making scheduled admission and/or transesophageal echocardiogram (TEE) unnecessary and therefore causing misutilization of healthcare resources. Emerging medical technology has allowed for monitoring of heart rhythm abnormalities. Objective A prospective multicenter study was designed to evaluate the diagnostic ability of a smart device ECG monitor to detect spontaneous conversion to SR in AF patients, preventing unnecessary admission and providing an earlier management. Methods A prospective multicenter study was designed including patients with first diagnosed, paroxysmal or persistent AF scheduled for ambulatory electrical cardioversion in cardiology departments of 7 hospitals of Spain. Patients were asked to submit ECG recordings to a central Corelab daily, twice a day and whenever they present symptoms, until cardioversion (spontaneous or scheduled) and a week afterwards. Whenever a spontaneous conversion to SR was detected, investigators were contacted to confirm SR and abort admission, likewise when AF recurrence after cardioversion was detected. Patients’ satisfaction was evaluated using a test for perceived utility and value, convenience, and accessibility. Results A total of 62 patients were enrolled (age 62±10 years). Baseline characteristics of the study population are described in the Table. Fifteen patients (24%) did not undergo CV as they showed spontaneous conversion to SR. Among 47 patients admitted for CV, it was successful in 41 (87%). One patient aborted CV because of atrial thrombus on TEE. During follow up after conversion to SR (spontaneous or electrical), recurrences of AF occurred in 20 of 56 patients (36%) correctly detected by the devices. At the end of the follow-up 41 of 56 patients (73%) remained in SR. Due to the early detection of spontaneous conversion to SR, a total of 15 admissions and 9 TEE were prevented and these resources used for other patients. Adherence was high with a rate of ECG transmission over 80% in 56 patients (90%). Perceived satisfaction was also high with an overall punctuation of 9 over 10 in the patient’s feedback test. Conclusion Digital devices for heart rhythm monitoring can optimize the management of AF patients scheduled for CV, avoiding unnecessary admissions and providing a more rational use of healthcare resources.
No takes yet. Share an insight, caveat, or question.
Mazuecos et al. (2024) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: