In an extension of our previous work, [Sergey L Bud'ko et al 2023 Supercond. Sci. Technol. 36 115001] the measurements of temperature dependent magnetization associated with trapped magnetic flux in a small single crystal of CaKFe₄As₄, using zero-field-cooled and field-cooled protocols were performed, on the same crystal, at ambient pressure without a pressure cell and at 2.2 GPa in a commercial diamond anvil cell (DAC), showing comparable results. The data show that with a proper care and understanding, trapped flux measurements in superconductors indeed can be performed on samples in DACs under pressure, as was done on superhydrides [V S Minkov et al 2023 Nat. Phys. 19 1293].
No takes yet. Share an insight, caveat, or question.
Bud’ko et al. (2024) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: