Answers are grounded in this paper and cite their sources.
Longan drying in Loei Province, Thailand. There were two types of dryers with capacity in 5,000 kgs and 10 kgs of type 1 and 2, respectively. The moisture content of longans inside and outside the dryer; type 1 decreased from 80.91% (w.b.) to 20.0%(w.b.), the moisture content of longan samples outside the dryer decreased to 40.0%(w.b.) within 5 days; type 2 decreased from 80.91%(w.b.) to 22.0%(w.b.), the moisture content of longan samples outside the dryer decreased to 45.0% (w.b.) within 5 days respectively. Heat transfer modeling results showed that the moisture content calculated from the model corresponding to the measured values the RMSE=0.5251, 0.4266 and =0.9655, 0.9745. The thermal efficiency of the dryer; type 1 has a thermal efficiency of 8.55%-25.27%; type 2 has a thermal efficiency of 4.42-26.11%.
No takes yet. Share an insight, caveat, or question.
Jagrapan Piwsaoad (2024) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: