The Atmospheric Chemistry Experiment Fourier Transform Spectrometer (ACE-FTS) is currently providing the only measurements of vertically resolved chlorodifluoromethane (HCFC-22) from space. This study assesses the ACE-FTS HCFC-22 v5.2 product in the upper troposphere and lower stratosphere, as well as simulations of HCFC-22 from a 39-year specified dynamics run of the Canadian Middle Atmosphere Model (CMAM39) in the same region. In general, ACE-FTS HCFC-22 observations tend to agree with subsampled CMAM39 data to within ±5 %, except for between ∼ 15 and 25 km in the extratropical regions where ACE-FTS exhibits a negative bias of 5 %–30 % and near 6 km in the tropics where ACE-FTS exhibits a bias of −15 %. When comparing against correlative satellite, aircraft, and balloon data, ACE-FTS typically exhibits a low bias on the order of 0 %–10 % between ∼ 5 and 15 km and is within ±15 % between ∼ 15 and 25 km. ACE-FTS, CMAM39, and surface flask measurements from the NOAA Global Monitoring Laboratory's surface air-sampling network all exhibit consistent tropospheric HCFC-22 trends ranging between 6.8 and 7.8 ppt yr−1 (within 95 % confidence) for 2004–2012 and between 3.1 and 4.7 ppt yr−1 (within 95 % confidence) for 2012–2018. Interhemispheric differences (IHDs) of HCFC-22 were also derived using ACE-FTS, NOAA, and CMAM39 data, and all three yielded consistent and correlated (r≥0.42) IHD time series, with the results indicating that surface IHD values decreased at a rate of 2.2 ± 1.1 ppt per decade between 2004 and 2018.
No takes yet. Share an insight, caveat, or question.
Kolonjari et al. (2024) studied this question.