Purpose: To present a novel technique that enables safe and effective cannulation of target vessels with challenging anatomy during fenestrated/branched endovascular aortic repair (F/B-EVAR). Technique: Following deployment of the F/B-EVAR endograft, the target vessels (TVs) are cannulated. The bundle wire technique provides a solution to challenging TVs and uses multiple fine atraumatic guidewires that together serve as a stiff guidewire. The technique can be executed in 2 ways using: (1) one 0.018 inch and one 0.014 inch guidewire or (2) three 0.014 inch guidewires. We demonstrate the technique in a case of a complex abdominal aortic aneurysm treated using branched EVAR in which the left renal artery with severe ostial stenosis was catheterized using the bundle wire technique. Conclusions: The bundle wire technique offers a technically feasible and economically viable solution for facilitating catheter and bridging stent delivery in anatomically challenging TVs during F/B-EVAR. It is a useful addition to the therapeutic armamentarium available to physicians for accessing demanding TVs.
No takes yet. Share an insight, caveat, or question.
Ali et al. (2024) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: