Answers are grounded in this paper and cite their sources.
Gas back-allocation evaluates process-efficiency in production domain by computing the contribution of individual wells to total production measured at surface facilities. In the case study, the previously deployed gas back-allocation method resulted in a substantial difference between measured and allocated gas volumes. To improve forecasting reliability, essential for all future expansion projects, the legacy approach needed to be revised and replaced by a more precise and robust methodology. The legacy method of gas back-allocation relied on well-test gas measurements and oil back-allocation factor. With inherent inaccuracies in well-test gas measurement, and the separate surface-nodes utilized to measure oil and gas, the resulting back-allocated gas volumes were substantially lower than actual. An innovative approach was proposed to reconcile gas production at individual wells using daily estimated oil production, and a combination of GOR from PVT and well-test measurements, to compute the total summation of produced gas and compare that with gas measured at each sub-center. This would imply relocating the gas back-allocation node from Asset level to sub-center level. The primary objective for method revision was to reduce inaccuracies introduced during gas-rate measurements at well-test level and further compounded by human error during validation of the test results. The revised logic introduced the concept of using guiderails of reservoir-specific GOR values, as obtained from PVT analyses and deploy an automated test validation process to filter-out all incorrect GOR values at the well-test level, which can be considered as the Input end for back allocation. Since gas volume computation at individual wells require both GOR and oil rates, accuracy was further enhanced by utilizing daily estimates of oil production per well, computed with the combination of latest well-test data, historical decline rates and well uptimes. At the output end, it was proposed to assign sub-centers, which are essentially the metering points for surface gas, as nodes for top level of the network to calculate gas back-allocation. With this method, each sub-center, attached to a specific field and reservoirs, would have its own gas back-allocation factor. This would also be a distinct departure from the previous method that assigned a single allocation factor for the entire asset. The case study suggests a novel approach of increasing computation accuracy for cases with restricted data availability or questionable accuracy of raw data. Implementation of the new logic revised the allocated gas to within 10% of the total measured gas volumes at the Asset level. It has further provided the opportunity to re-visit the gas metering accuracy and meter re-calibration requirements for each sub-center and evaluate gaps in historical PVT data for individual fields and reservoirs.
No takes yet. Share an insight, caveat, or question.
Sanyal et al. (2024) studied this question.
Synapse has enriched 8 closely related papers on similar clinical questions. Consider them for comparative context: