Answers are grounded in this paper and cite their sources.
BackgroundStemless humeral components are being clinically investigated for reverse shoulder arthroplasty (RSA) procedures. There is, however, a paucity of basic science literature on the surgical parameters that influence the success of these procedures. Therefore, this cadaveric biomechanical study evaluated the neck shaft angle (NSA) of implantation on the survivability and performance of stemless RSA humeral components during cyclical loading.MethodsTwelve paired cadaveric humeri were implanted with stemless RSA humeral components at NSAs of 135° and 145°. Implant-bone motion at the periphery of the implant was measured with three optical machine vision USB3 cameras outfitted with c-mount premium lenses and quantified with ProAnalyst® software. A custom three-dimensional loading apparatus was used to cyclically apply three loading directions representative of physiological states at five progressively increasing loading magnitudes. Stemless 135° and 145° implants were compared based on the maximum implant-bone relative distraction detected, as well as the survivorship of the implants throughout the loading protocol.ResultsPrimary fixation and implant biomechanical survivorship were substantially better in the 145° NSA implants. The 135° NSA implants elicited significantly higher implant-bone distractions during cyclical loading (P = 0.001), and implant survivorship was considerably lower in the 135° NSA specimens when compared to the 145° NSA specimens (135° NSA: 0%, 145° NSA: 50%) (P < 0.001).ConclusionsNeck shaft angle is a modifiable parameter that influences time-zero implant stability, as well as the early survivorship of the stemless RSA humeral components tested in this study. Neck shaft angle resections of 145º appear to promote better stability than those utilizing 135º neck shaft angles during early postoperative eccentric loads. Further studies are required to assess if other stemless reversed humeral implant designs have improved time-zero fixation at higher neck-shaft angles. Stemless humeral components are being clinically investigated for reverse shoulder arthroplasty (RSA) procedures. There is, however, a paucity of basic science literature on the surgical parameters that influence the success of these procedures. Therefore, this cadaveric biomechanical study evaluated the neck shaft angle (NSA) of implantation on the survivability and performance of stemless RSA humeral components during cyclical loading. Twelve paired cadaveric humeri were implanted with stemless RSA humeral components at NSAs of 135° and 145°. Implant-bone motion at the periphery of the implant was measured with three optical machine vision USB3 cameras outfitted with c-mount premium lenses and quantified with ProAnalyst® software. A custom three-dimensional loading apparatus was used to cyclically apply three loading directions representative of physiological states at five progressively increasing loading magnitudes. Stemless 135° and 145° implants were compared based on the maximum implant-bone relative distraction detected, as well as the survivorship of the implants throughout the loading protocol. Primary fixation and implant biomechanical survivorship were substantially better in the 145° NSA implants. The 135° NSA implants elicited significantly higher implant-bone distractions during cyclical loading (P = 0.001), and implant survivorship was considerably lower in the 135° NSA specimens when compared to the 145° NSA specimens (135° NSA: 0%, 145° NSA: 50%) (P < 0.001). Neck shaft angle is a modifiable parameter that influences time-zero implant stability, as well as the early survivorship of the stemless RSA humeral components tested in this study. Neck shaft angle resections of 145º appear to promote better stability than those utilizing 135º neck shaft angles during early postoperative eccentric loads. Further studies are required to assess if other stemless reversed humeral implant designs have improved time-zero fixation at higher neck-shaft angles.
No takes yet. Share an insight, caveat, or question.
Cunningham et al. (2024) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: