This paper presents the design and simulation process of a bi-directional CLLC resonant DC-DC converter with an integrated transformer for electric vehicle system (EV). The value of C-L-L-C will be calculated using the First Harmonic Approximation (FHA) method. A new close-loop algorithm control for increasing fast response is proposed. Besides, the synchronous rectification (SR) method will be combined with a new algorithm controlling turn-on and turn-off delays on the rectifier side. The simulation uses the simulation software PSIM® with 700W on the high-voltage side and 600W on the low-voltage side. The result of time response is reduced compared with the conventional algorithm (1.25ms in new algorithm and 2.25ms in conventional algorithm).
No takes yet. Share an insight, caveat, or question.
Ngo et al. (2024) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: