PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
April 16, 2024npj Flexible Electronics17 citationsOpen Access

Stroke-volume-allocation model enabling wearable sensors for vascular age and cardiovascular disease assessment

View Full Paper
SQShirong QiuBYBryan P.Y. YanNZNi Zhao

Key Points

Key points are not available for this paper at this time.

Abstract

Abstract Frequent and unobtrusive monitoring of cardiovascular conditions with consumer electronics is a widely pursued goal, since it provides the most economic and effective way of preventing and managing cardiovascular diseases (CVDs) ─ the leading causes of death worldwide. However, most current wearable and flexible devices can only support the measurement of one or two types of vital signs, such as heart rate and blood oxygen level, due to the lack of physiological models to link the measured signals to cardiovascular conditions. Here, we report a stroke-volume allocation (SVA) model to quantify the cushioning function of arteries and empower nearly all existing cardiac sensors with new functions, including arterial stiffness evaluation, dynamic blood pressure tracking and classification of CVD-related heart damage. Large-scale clinical data testing involving a hybrid dataset taken from 6 hospitals/research institutes (9 open databases and 4 self-built databases from 878 subjects in total) and diverse measurement approaches was carried out to validate the SVA model. The results show that the SVA-based parameters correlate well with the gold-standard measurements in arterial stiffness and blood pressure and outperform the commonly used vital sign (e.g., blood pressure) alone in detecting abnormalities in cardiovascular systems.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Qiu et al. (2024) studied this question.

synapsesocial.com/papers/68e6ee09b6db64358766894bhttps://doi.org/10.1038/s41528-024-00307-1
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Withings Body Cardio Versus Gold Standards of Pulse-Wave Velocity and Body Composition2020 · 15 citations
  2. 2Left Ventricular Ejection Time in Valvular Aortic Stenosis1973 · 54 citations
  3. 3Determinants of pulse wave velocity in healthy people and in the presence of cardiovascular risk factors: ‘establishing normal and reference values’2010 · 2,078 citations
  4. 4Paradoxical Low-Flow, Low-Gradient Severe Aortic Stenosis Despite Preserved Ejection Fraction Is Associated With Higher Afterload and Reduced Survival2007 · 958 citations
  5. 5Disruption of Ultradian and Circadian Rhythms of Blood Pressure in Nondipper Hypertensive Patients2004 · 21 citations