A Near-Infrared (NIR) ratiometric luminescence thermometer with the composition of Yb1Gd2Al1.98Cr0.02Ga3O12 was prepared and studied. When excited by 660 nm in the first biological transparent window (BTW), the sample shows a peak structure of around 1000 nm due to the 2F5/2 → 2F7/2 transitions of Yb3+ via the energy transfer process from Cr3+. Due to the Boltzmann distribution, the Yb3+ PL intensities in the shorter wavelength side (i.e., 1st BTW) and longer wavelength side (i.e., 2nd BTW) exhibit opposite temperature dependencies. The luminescence intensity ratio (LIR) of Yb3+ in shorter and longer wavelength ranges works as a luminescence thermometer with a relative sensitivity of 0.55% K−1 at 310 K. In addition, YbGd2Al1.98Cr0.02Ga3O12 can also be employed for temperature sensing based on the LIR of Cr3+ (2E → 4A2) at around 700 nm and Yb3+ (2F5/2 → 2F7/2) at around 1000 nm, achieving a remarkable relative sensitivity of 2.69% at 100 K. This study confirms that the YbGd2Al1.98Cr0.02Ga3O12 thermometer fulfills the requirements for biological temperature measurements.
No takes yet. Share an insight, caveat, or question.
Zhang et al. (2024) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: