Answers are grounded in this paper and cite their sources.
You have accessJournal of UrologyFemale Voiding Dysfunction/ Pelvic Floor Disorders/ Incontinence/ Neuro-Urology (V02)1 May 2024V02-02 NOVEL TECHNIQUES TO REMOVE FRACTURED AND INTACT SACRAL LEADS Jackson Stachelek, Natalija Kovacevic, Jason Gilleran, and Kenneth Peters Jackson StachelekJackson Stachelek , Natalija KovacevicNatalija Kovacevic , Jason GilleranJason Gilleran , and Kenneth PetersKenneth Peters View All Author Informationhttps://doi.org/10.1097/01.JU.0001008636.33664.3e.02AboutPDF ToolsAdd to favoritesDownload CitationsTrack CitationsPermissionsReprints ShareFacebookLinked InTwitterEmail Abstract INTRODUCTION AND OBJECTIVE: SNM is currently indicated by the FDA for urinary frequency and urgency, urge incontinence, non-obstructive urinary retention, and fecal incontinence. Off-label, SNM may improve pelvic pain, interstitial cystitis, dyspareunia, pelvic floor dysfunction, sexual dysfunction, and persistent genital arousal. Neuromodulation is achieved by implanted electrical leads which stimulate sacral nerve roots. The first iterations of stimulator implants were not compatible with MRI and many patients still retain MRI-incompatible titanium leads which can heat up during magnetic imaging. For this reason, as well as lead migration, loss of efficacy, or adverse events, implanted leads may need to be removed. Current medical literature offers few techniques to successfully remove outdated or ineffective leads. We present novel, effective methods of intact and broken lead removal in MRI and non-MRI compatible interstim devices. METHODS: Lead removal is demonstrated in two patients. First, a 53- year-old-female who needs Interstim removal and replacement to the MRI compatible version. The second patient is a 54-year-old woman with an MRI compatible device that fractured below the bone plate during initial removal. RESULTS: In the first patient, a hemostat was used to grasp and pull the inner wire. This process results in a wireless "ghost lead", which is MRI-compatible. However, by pulling the inner wire, the distal lead contracts, creating an accordion effect on its tines. The tines are freed from the surrounding tissue, completely removing the intact lead. Our second patient is a 54-year-old female with a MRI-compatible device. Newer leads differ from older models in that they have firmer adherence to the wire. Even in this case, our same technique can be applied. Occasionally during lead removal, the lead can break. Often times the breakage occurs above the bone plate at which point the incision is extended and dissection is performed down to the level of the broken lead. The lead is then removed. Rarely, the lead breaks below the sacral bone plate, resulting in a more challenging removal. To remove the lead, an incision is made over the sacrum. The lead introducer is advanced into the foramen alongside the fractured lead and the inner trocar is removed. Next, a flexible grasper is advanced through the lead introducer down to the foramen. Under fluoroscopic guidance the lead introducer and grasper are manipulated down to the fractured lead which is grasped and removed intact. CONCLUSIONS: In conclusion,we present minimally invasive methods for easier lead removal and fractured lead removal, both above and below the sacral bone plate. Source of Funding: None © 2024 by American Urological Association Education and Research, Inc.FiguresReferencesRelatedDetails Volume 211Issue 5SMay 2024Page: e100 Advertisement Copyright & Permissions© 2024 by American Urological Association Education and Research, Inc.Metrics Author Information Jackson Stachelek More articles by this author Natalija Kovacevic More articles by this author Jason Gilleran More articles by this author Kenneth Peters More articles by this author Expand All Advertisement PDF downloadLoading ...
No takes yet. Share an insight, caveat, or question.
Stachelek et al. (2024) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: