PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
April 9, 2024International Sustainable Energy Conference - Proceedings1 citationsOpen Access

Survey of Industrial Excess Heat Potentials in Austria

View Full Paper
AHAndreas HammerELElisabeth LachnerTKThomas Kienberger

Key Points

Key points are not available for this paper at this time.

Abstract

In the research and service study for the Energy Transition 2050 program, the technical excess heat potentials for both energy-intensive and energy-extensive Austrian industry were surveyed. A bottom-up approach for most of the energy-intensive industry and a top-down approach for most of the energy-extensive industry were used by the consortium under the leadership of the Chair of Energy Network Technology EVT of Montanuniversität Leoben. The surveyed potentials were classified according to temperature level of excess heat, origin from the process, spatial occurrence and industry sectors. In order to estimate the future industrial excess heat potentials, a database of the innovation network "New Energy for Industry" (NEFI) was used. For the geographical localization, the results were integrated into the existing Austrian Heat Map, which enables a comparison with heat demand densities and existing heating networks. A technical excess heat potential of about 34 TWh could be identified. Thereof, about 300 companies of the energy-intensive industry, which were mainly calculated by the bottom-up method, account for a technical excess heat potential of about 26 TWh. For the energy-extensive industry, an excess heat potential of about 4 TWh was identified for more than 1500 companies using mostly the statistical top-down method. Due to existing know-how in the consortium, the technical excess heat potentials of more than 600 sewage treatment plants could also be estimated at approx. 4 TWh.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Hammer et al. (2024) studied this question.

synapsesocial.com/papers/68e6fdb8b6db64358767853ehttps://doi.org/10.52825/isec.v1i.1146
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 15th generation district heating and cooling systems: A review of existing cases in Europe2019 · 657 citations
  2. 2Spatial modelling of industrial heat loads and recovery potentials in the UK2010 · 141 citations
  3. 3Methods to estimate the industrial waste heat potential of regions – A categorization and literature review2014 · 159 citations
  4. 4Heat pump efficiency in fifth generation ultra-low temperature district heating networks using a wastewater heat source2021 · 69 citations