The paper presents an analysis of the innovative connector for manufacturing a steel–concrete composite beam. The connector consists of a corrugated metal sheet in the shape of a dovetail and shot nails. The nails are shot through the sheet fold into the flange of the steel I-section. Experimental studies of push-out tests were carried out. The conducted tests proved that the proposed solution can be applied as the fastener for steel–concrete composite beams for the construction of ceilings in utility public buildings with small beam’s span. Considering the criteria presented in the Eurocode 4 standard and the results of the experiments, it was proven that all analyzed types of fasteners are ductile. The connector made of sheet with a thickness of 1.00 mm and 2 nails is characterized by a breaking load of 30.83 kN. The load-bearing capacity of the fastener can be adjusted by changing the corrugated sheet thickness and changing the number of nails shot in the single fold of the sheet.