The article explores the susceptibility of a deep neural network implemented on a Xilinx Ultrascale+ MPSoC to single event effects under pulsed laser irradiations. The irradiation test involves scanning the MPSoC using a 1064nm wavelength single-photon laser with three different energy levels: 5nJ, 8nJ and 11nJ. During these scans, three types of soft errors were detected: misidentification number varied, system halt, and system re-initialization. The distribution of these soft errors across the MPSoC is determined. Notably, a significant burnout occurs when the current reaches approximately 1000mA, and this phenomenon does not reoccur once the threshold current is set to 800mA. Additionally, software fault injection is performed, and misidentification number variation and system halt soft errors are also detected during this process. These findings confirm a possible source of the observed soft errors in pulsed laser irradiation. It suggests that single event upsets in the configuration memory could be a potential cause of the observed soft errors during laser scanning.
No takes yet. Share an insight, caveat, or question.
Yang et al. (2024) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: