Analysis demonstrates hydrodynamic calculations optimize thermal simulator testing under blast effects, suggesting improved resource use.
The Defense Nuclear Agency (DNA), a Department of Defense agency, has recently completed construction of the world’s largest known shock tube, and has begun the process of characterizing the facility performance. This chock tube, called the Large Blast/Thermal Simulator (LB/TS) was built to provide a test facility which allows evaluation of the performance, survivability and vulnerability of DoD materiel under air blast, thermal and combined loading. It is the only facility in the world which permits full scale synergistic testing of equipment to the listed weapons effects. The shock tube is a half cylinder 20 meters inside diameter, with meter thick concrete walls, and 170 meters long - with the test station located 105 meters downstream of the shock driver system. The shock is driven by nine driver tubes which are 1.8 meters in diameter and range in length from approximately 15 to 60 meters, and have a combined maximum volume of 580 cubic meters. Nitrogen gas is used to drive the shock system; the design of the facility permits pressures up to 2250 PSI and gas temperatures to 725 degrees F in the driver tubes at test execution. A LOX-AL thermal radiation source capable of producing 80 cal/cm2-sec flux, for a total of 800 cal/cm2 fluence provides the other main aspect of the simulator. The LB/TS operates with the variables of driver gas pressure, driver gas temperature, baffle size (varies the throat nozzle diameter), and rarefaction wave eliminator (RWE) performance. The RWE acts to mitigate the effects of a rarefaction wave travelling upstream from the shock tube exit back to the test section. This is required to permit the facility to simulate air blast of long duration as is seen in weapons effects, rather than shorter duration simple shocks. Each full test which is performed to characterize the facility performance costs on the order of tens of thousands of dollars; consequently a suite of 2- and 3-D hydrodynamic calculations have been performed in order to optimize the actual tests, and the variables of the simulator with regard to the environments produced. The calculations have been performed based on combinations of four variables: RDAP - Ratio of Driver to Ambient Pressure RDAT - Ratio of Driver to Ambient Temperature Volume - Volume of gas in the driver tubes Baffle - Percentage of throat area open (40%, 100%) This paper will discuss the demonstrated effectiveness of using CFD to optimize the performance of a machine which operates with several variables. The use of CFD permitted us to realize that 10% throat baffles, originally planned for use, would not work, thus saving limited resources of material and time, and has permitted optimization of the actual facility process, from test design through execution. Actual test data will be presented in comparison with results of the CFD work. Specific attention will be given to the variables of driver gas temperature and pressure, and the resulting wide range of environments produced by the virtually infinite combinations, as well as the limitations which physics and the facility operational constraints impose.
No takes yet. Share an insight, caveat, or question.
Seiden-Martinez et al. (1995) studied this question.
Synapse has enriched 8 closely related papers on similar clinical questions. Consider them for comparative context: