Radon, Thoron and their short-lived daughters have a high contribution to background radiation, as long-term exposure causes the risk of lung cancer. In current study, five types of building materials with a total 55 samples in Al-Shatra City, Dhi-Qar Governorate, Iraq collected to measure the radon and thoron concentration by using CR-39 solid state nuclear track detector. The results showed that the average radon concentrations in all samples were (103.53±55.94) Bqm −3 , while the average thoron concentration was (53.20±44.69) Bqm −3 . On the other hand, the annual effective dose of radon ranged between (0.85-6.46) msvy −1 , with an average of 2.61msvy −1 . While, for thoron concentration was ranged between (0.12-3.28) msvy −1 , with an average of 1.49 msvy −1 . The annual effective dose was found acceptable limit (3-10 msvy −1 ) recommended by the International Commission on Radiological Protection (ICRP). On the other side, the average Polonium concentrations ( 218 Po, 214 Po) have been found to be 2.053 KBqm −3 , 0.866 KBqm −3 , respectively.
No takes yet. Share an insight, caveat, or question.
Elewee et al. (2024) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: