In order to study the effects of different parameters on the mechanical properties of composite mixed (bolted/bonded) joint structure, this paper built a CFRP/steel single shear double-nail mixed joint structure model based on the known material parameters, Hashin criterion and quade adhesive layer failure criterion, and established a finite element simulation model in Abaqus software. Parameters such as lay-up Angle, lay-up thickness, hole size, bolt end distance and so on were changed respectively. The simulation results show that when the lay-up Angle is [0/45/90/-45]2s, the lay-up thickness is 0.26mm, the opening size is 5mm, and the end distance is 7.5mm, the overall connection strength of the structure is the highest.
No takes yet. Share an insight, caveat, or question.
ying et al. (2024) studied this question.