To enhance a home refrigerator’s refrigeration system’s performance, three types of nanoparticles (TiO 2 , CNTs, and SiO 2 ) were used to produce nanolubricants. The experiments were conducted with different charges of 50 and 60 g for R600a refrigerants, which a digital charging scale was used to measure. The inlet and exit temperature of the system’s components were measured using K-type thermocouples. The system was outfitted with two pressure gauges for measuring the pressures at suction and discharge. The obtained results show the system’s COP increases with nanolubricant-enhanced refrigerants, with the power of the based lubricant, TiO 2 , CNTs, and SiO 2 nanolubricant being 0.0821, 0.0612, 0.0673, and 0.0702 kW, respectively. Therefore, nano-enhanced refrigerant can successfully replace R600a in the based lubricant in domestic refrigerators.
No takes yet. Share an insight, caveat, or question.
Madyira et al. (2024) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: