A BSTRACT Introduction: Computed tomography (CT) scan has high sensitivity and specificity for numerous conditions. The images produced by a CT scanner can be enhanced using iodinated contrast media. Significant hemodynamic changes are seen with rapid intravenous contrast media injection. The average acceptable blood pressure (BP) value is 120/80 mmHg. Many studies have related hypertensive crises with high-osmolar contrast media, whereas its relation with low-osmolar contrast media is still unclear. This study aims to evaluate the effect of nonionic iodinated contrast media on BP during contrast-enhanced CT (CECT) of the abdomen. Materials and Methods: A cross-sectional study was conducted from April 2022 to August 2023. A total of 146 subjects (73 males and 73 females were included in the study). Statistical analysis of data was done using SPSS 23.0. A comparison of systolic BP and diastolic BP across the three periods was done using repeated measures of ANOVA. A between-group comparison was performed by unpaired t -test. The level of significance was set as 5%. All subjects underwent a CECT abdomen, including a plain, arterial, and venous phase. A bolus of 80 mL of Ultravist was administered. BP was measured before the contrast injection (baseline value), between the arterial and venous phases, and 3 min after the contrast injection. Results: Injection of nonionic contrast media caused a decrease in BP among subjects. The mean systolic BP readings before contrast injection in males and females were 127.5 ± 8 mmHg and 122.8 ± 8.4 mmHg, respectively. The mean diastolic BP before contrast injection was 79.2 ± 6.4 and 76 ± 6.4 mmHg among males and females, respectively. For systolic, these values decreased to 123 ± 10.3 mmHg in males and in females to 115 ± 14.6 mmHg when measured between arterial and venous phases. Similarly, for diastolic BP, the mean values recorded between the arterial-venous phase reduced to 76.7 ± 9.3 mmHg and 72.3 ± 10 mmHg, respectively. The BP readings, however, increased near baseline value when measured 3 min after the injection. The mean systolic BP measured 126.1 ± 8.5 mmHg and 124.9 ± 11.8 mmHg for males and females at 3 min after injection. Similarly, the mean diastolic BP values taken after 3 min of contrast injection were 78.3 ± 6.5 mmHg and 76.2 ± 7 mmHg in males and females, respectively, P < 0.001. BP in both male and female groups was affected similarly. Conclusion: Bolus administration of 80 mL of Ultravist reduced BP. This reduction was short-term and got back to normal within a few minutes. The contrast media similarly affected both genders. The BP changes had no clinical significance.
No takes yet. Share an insight, caveat, or question.
Betkar et al. (2024) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: