According to a recently proposed nuclear safeguards technique, monitoring the power-normalized, ex-core neutron detection rate over time could be used to detect undeclared changes to the fissile composition of a reactor core. In this study, Monte Carlo simulations have been used to verify some of the underlying assumptions of this technique and the possibilities of using it to detect undeclared fuel substitutions during the first 2-year cycle of a light water small modular reactor. Depletion calculations and neutron transport simulations were used to study the changes in the power-normalized neutron leakage rate Jb/Pcore through the core barrel upon fuel substitutions and whether these changes are fully explained by changes in the core fissile composition. Several substitution scenarios have been studied, where partially depleted fuel assemblies were substituted with fresh fuel assemblies after 1 year of irradiation.
No takes yet. Share an insight, caveat, or question.
Preston et al. (2024) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: