This paper investigates and compares the performance of three-phase inverters against sets of single-phase full-bridge inverters in motor drive applications. Comparisons are made for a common semiconductor device area and rms phase current ripple, and the regions of the design space in which each topology is advantageous are identified. It is found that separate full-bridge inverters are preferable for designs in which switching losses are dominant, whereas three-phase inverters are preferable for designs in which conduction losses are dominant. This result suggests that individual phase drive is desirable in applications requiring high switching frequencies, as in high-speed, low-inductance machines. A 10-kW system is constructed to enable experimental comparisons. The experimental results conducted at 3.6 kW validate analytical and simulation findings.
No takes yet. Share an insight, caveat, or question.
Qasim et al. (2024) studied this question.
Synapse has enriched 3 closely related papers on similar clinical questions. Consider them for comparative context: