Answers are grounded in this paper and cite their sources.
This paper describes a novel compact dual-band dual-polarization feed design with reduced cross-section. This is achieved using a developable H-plane coupler wrapped around the orthomode junction. This design approach enables to reduce significantly the cross-section of the feed without compromising its longitudinal length. A prototype of a specific design in the K/K <inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">a</inf> - band is described and experimental results are reported, showing good agreement between simulated and measured data. The functional part of the feed occupies a volume of only 18 mm × 18 mm × 30 mm. The mechanical multilayer assembly design of the prototype has an hexagonal outline cross-section compatible with a feed spacing as small as 25 mm. The feed spacing may be reduced further using additive manufacturing techniques for the design of highly integrated clusters. This feed design is of interest for the development of innovative multiple-feed-per-beam feed clusters onboard next-generation broadband communication satellites.
No takes yet. Share an insight, caveat, or question.
Nelson J. G. Fonseca (2024) studied this question.