This study analyzed the dentin shear bond strength (SBS) of an etch-and-rinse (ER) or a self-etch (SE) adhesive incorporated with multifunctional polyhedral oligomeric silsesquioxanes (MA-POSS-8). An ER adhesive (Solobond Plus, VOCO GmbH, Cuxhaven, Germany) and a universal adhesive applied in SE mode (Scotchbond Universal, 3M, St. Paul, MN, USA) were infiltrated with MA-POSS-8 (Hybrid Plastics Inc., Hattiesburg, MS, USA) at 5 wt.% or 10 wt.%. Pure adhesives served as controls. Bovine dentin specimens were conditioned with one of the adhesives prior to the application of a nano-hybrid composite (Venus Diamond A3, Kulzer, Hanau, Germany). SBS and failure modes were determined after water storage for 24 h, 6 months, 12 months, or 24 months (each subgroup n = 20). Statistical analysis was performed using ANOVAs, Weibull statistics, and χ2 tests (p < 0.05). SBSs for the control groups after 24 h were 17.4 ± 4.9 MPa for the ER adhesive and 19.1 ± 5.2 MPa for the universal adhesive. After 24 months, the SBS of the ER adhesive was significantly higher for 5 wt.% MA-POSS-8 (17.9 ± 5.1 MPa) than for the control group (14.6 ± 3.6 MPa) and 10 wt.% MA-POSS-8 (12.8 ± 4.1 MPa), and more cohesive failures were observed. The SBS of the universal adhesive increased during aging, irrespective of the MA-POSS-8 concentration. 5 wt.% MA-POSS-8 improves the SBS of the ER adhesive and does not impair the SBS of the SE adhesive.
No takes yet. Share an insight, caveat, or question.
Biermann et al. (2024) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: