Answers are grounded in this paper and cite their sources.
In this paper, we present the design and characterization of a fifth-order fundamental mode and fifth-order higher-order mode substrate-integrated waveguide filter in E-band. Low-cost Rogers3003 printed-circuit board technology is used to fabricate the filters designed for a center frequency of 73.5 GHz and a bandwidth of 4.4 GHz. A WR-10 to SIW slot transition is implemented to enable a standalone characterization of the SIW filters. The measured and de-embedded insertion losses are 1.43 and 1.78 dB for the fundamental and higher order mode filter, respectively. The return loss of both filters is less than -6 dB over their entire bandwidth and the stop-band suppression is better than 40 dB.