TRopIcal DEep-sea Neutrino Telescope (TRIDENT) plans to incorporate silicon photomultipliers (SiPMs) with superior time resolution in addition to photomultiplier tubes (PMTs) into its detection units, namely hybrid Optical Digital Modules (hDOMs), to improve its angular resolution. However, the time resolution significantly degrades for large-area SiPMs due to the increased parasitic capacitance, posing significant challenges for the readout electronics of SiPMs in hDOM. We designed the front-end readout electronics for large-area SiPM arrays dedicated to high-precision time measurements, which consists of a high-speed pre-amplifier based on transformers (MABA-007159) and radio frequency (RF) amplifiers (BGA2803), a series-parallel combination SiPM array with reduced capacitance, and an analog multi-channel summing circuit. We measured the single photon time resolution (SPTR) of a 4×4 SiPM (Hamamatsu S13360-3050PE) array (12×12~mm²) of approximately 300 ps FWHM with a power consumption of less than 100 mW. This front-end readout design enables the large-area SiPM array to achieve high-precision SPTR with low power consumption.