PurposeJoint space width (JSW) is a common metric used to evaluate joint structure on plain radiographs. For the hand, quantitative techniques are available for evaluation of the JSW of finger joints; however, such techniques have been difficult to establish for the trapeziometacarpal (TMC) joint. This study aimed to develop a validated method for measuring the radiographic joint space of the healthy TMC joint.ApproachComputed tomographic scans were taken of 15 cadaveric hands. The location of a JSW analysis region on the articular surface of the first metacarpal was established in 3D space and standardized in a 2D projection. The standardized region was applied to simulated radiographic images. A correction factor was defined as the ratio of the CT-based and radiograph-based joint space measurements. Leave-one-out validation was used to correct the radiograph-based measurements. A t-test was used to evaluate the difference between CT-based and corrected radiograph-based measurements (α=0.05).ResultsThe CT-based and radiograph-based measurements of JSW were 3.61±0.72 mm and 2.18±0.40 mm, respectively. The correction factor for radiograph-based joint space was 1.69±0.41. Before correction, the difference between the CT-based and radiograph-based joint space was 1.43 mm [95% CI: 0.99−1.86 mm; p<0.001]. After correction, the difference was −0.11 mm [95% CI: −0.63−0.41 mm; p=0.669].ConclusionsCorrected measurements of radiographic TMC JSW agreed well with CT-measured JSW. With in-vivo validation, the developed methodology has potential for automated and accurate radiographic measurement of TMC JSW.
No takes yet. Share an insight, caveat, or question.
Jordan et al. (2024) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: