The internal impedance of a battery can be used to evaluate the capacity and health of a Li-ion battery as well as provide information for battery modeling. This impedance can be measured using electrochemical-impedance-spectroscopy where the cell is perturbed by a sinusoidal signal at discrete frequencies or by using broadband perturbation signals such as pseudo-random-sequences. This paper discusses the design considerations for the pseudo-random impulse sequence generator for the Li-ion battery impedance measurements. The effects of the various parameters such as the series RLC circuit parameters and the input DC voltage on the perturbation signal are evaluated through simulation and a laboratory experiment respectively. It is shown that the capacitor can be tuned to improve the low-frequency characteristics of the perturbation signal while the inductor can be used to control spectral characteristics in the higher-frequency band. The resistance and input DC voltage, on the other hand, control the overall magnitude of the perturbation signal spectral energy.