By utilizing Field Programmable Gate Arrays in a configuration similar to that of the Mirror Langmuir Probe, it is possible to bias a single probe at three precise voltages in sequence. These voltages can be dynamically adjusted in real-time based on the measured plasma electron temperature to ensure the transition region is always sampled. The first results have been obtained by employing this method and have generated real-time outputs of electron temperature, ion saturation current, and floating potential on a low temperature pulsed-DC magnetron at 500 kHz. These results are in good agreement with the analysis of a conventionally swept Langmuir probe. This probe is designed with the intention of being implemented on MAST-U to aid in the study of exhaust physics and enable further investigation into filamentary behavior.
No takes yet. Share an insight, caveat, or question.
Hickling et al. (2024) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: