This is the authors' abstract. We don't add key points for this paper.
The paper presents the results of experimental and model studies of the pressure swing adsorption (PSA) process in a column with a zeolite 13X bed with a height of 0.5 m. The gas mixture consisted of CO 2 (10–20%), N 2 , and H 2 O (RH 50%) in different ratios. As a result of the column tests, concentration, and temperature evolutions were obtained for each of the adsorption and desorption stages, which were used to determine the breakthrough and bed saturation times and other parameters important for the analysis of the column operation. A mathematical model of the PSA process for the separation of CO 2 from the gas mixture was developed. The system of second-order partial differential equations was solved using Matlab software. The research focuses on adsorptive CO 2 capture and shows the influence of water vapor and operational parameters on the quality of model validation.
Answers are grounded in this paper and cite their sources.
No takes yet. Share an insight, caveat, or question.
Aleksandrzak et al. (2024) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: