Answers are grounded in this paper and cite their sources.
Olaparib and Bevacizumab are anti-cancer agents. A new stability indicating RP-HPLC technique has been developed and validated for the simultaneous assay of Olaparib and Bevacizumab using Inertsil ODS column with UV detection at 258 nm within a run time of 6 minutes where Olaparib was eluted at 2.336 min and that of Bevacizumab at 4.873 min. Linearity was observed over the concentration range 37.50-225 µg/mL for Olaparib and 6.25-37.50 µg/mL for Bevacizumab respectively and the regression equations were found to be y=16815.19x+22410.75 and y=14512.58x+2387.04 for Olaparib and Bevacizumab respectively. The LOD was found to be 0.9 μg/ml and 0.1500 μg/mL whereas the LOQ was found to be 3.00 μg/mL and 0.5000 μg/mL for Olaparib and Bevacizumab respectively.
No takes yet. Share an insight, caveat, or question.
DK et al. (2024) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: