We performed an investigation of tungsten ionic species presence in hydrogen plasmas in contact with a tungsten surface, both in the presence of air impurities and when injected with argon. The study was carried out in a magnetron sputtering system complemented with mass spectrometry diagnostics. Our findings reveal that these plasmas encompass a diverse range of tungsten molecular ionic species in the mass range of 180–250 amu, broadly described as WH x N y O z + ( x = 0–3; y = 0–2; z = 0–3). The validity of these results was further confirmed through dedicated mass spectrometry investigations involving tungsten sputtering discharges in argon–nitrogen and argon–oxygen mixtures.
No takes yet. Share an insight, caveat, or question.
Stoica et al. (2024) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: