Analysis of Bolt Fracture Failure of Floating Head Cover for Heat Exchanger in Medium Pressure Hydrogenation Unit

View Full Paper
Ask AI
Bookmark
Share

Authors

HHHuasheng HuLWLei WangJLJiayue Liu

Discussion

Loading...

Member takes

Overview

Investigation reveals sulfide stress corrosion cracking as the main cause of bolt fracture in a heat exchanger.

Key Points

  • The primary cause of the bolt fracture is sulfide stress corrosion cracking in a wet hydrogen sulfide environment.
  • High-strength steel bolts showed high hardness but reduced impact toughness due to harsh working conditions.
  • Corrosion pits on the stud surface led to an instantaneous fracture near the center of the bolt.
  • Recommendations include sulfur content control and improved bolt inspection to prevent future failures.

Cite This Study

Hu et al. (2025) studied this question.

synapsesocial.com/papers/68e8439a9989581a2fd4e1f6https://doi.org/10.1115/pvp2025-152850
View Full Paper
Ask AI
Bookmark
Share

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Hydrogen-induced Fractures in Large Fasteners2026
  2. 2Root cause analysis of the brittle fracture of pipes of boiler heating surfaces after long-term operation2024 · 1 citations
  3. 3Failure Mechanism Analysis of 25Cr2MoV Bolt Fracture2026
  4. 4Failure Analysis of a Heat Exchanger in the Sour Water Unit of an Oil Refinery due to Ammonium Bisulfide Corrosion2026 · 1 citations
  5. 5Analysis of Causes and Protective Measures against Corrosion Perforation in the Shell-Side Outlet Flange of a Sour Water Steam Heater2024