This research presents models for single-phase and two-phase flow in high-pressure systems, revealing the influence of parameters like gas type and pressure.
Relief devices for high-pressure systems are mostly calculated using empirical methods as outlined in the API 520 [1], which often neglect the process conditions of the mixture. The sizing of these relief devices uses a discharge coefficient that acts as a correction factor to account for flow frictions, valve geometry factors, and other things that result in a lower relief flow than theoretically expected. These values are determined by manufacturers using non-reactive substances under standard conditions. The present work is intended to provide an in-depth understanding of the relief process of polymerization mixtures under process conditions. Therefore, the transient relief model of ZINK [2] based on an isentropic nozzle model and a real gas equation of state is used to describe the single-phase flow. For the description of a two-phase flow, a transient model based on the homogeneous non-equilibrium model from DIENER and SCHMIDT (HNE-DS) [3] is developed. Further, the development of a model to calculate the temperature and pressure loss at the downstream valve body is presented. Both models are compared with pressure and temperature data from high-pressure relief experiments. The combination of both models allows to investigate the influence different parameters like gas type, starting pressure or temperature have on the relief process.
No takes yet. Share an insight, caveat, or question.
Dyck et al. (2025) studied this question.