Answers are grounded in this paper and cite their sources.
Electrochemical method quantifies meloxicam in pharmaceuticals, suggesting enhanced accuracy for dosage monitoring.
Meloxicam (MEL) is a nonsteroidal anti‐inflammatory medication with antipyretic, anti‐inflammatory, and analgesic properties. Establishing a sensitive and reliable method to monitor MEL in pharmaceutical formulations is critical to ensure dosing accuracy and guarantee therapeutic efficacy. Herein, a simple electrochemical method was developed for the determination of MEL levels using a TiO 2 ‐Ag‐reduced graphene oxide (TiO 2 ‐Ag‐rGO) nanocomposite‐modified electrode in pH 3.0 Britton–Robinson (BR) buffer via the differential pulse voltammetric (DPV) technique. The prepared TiO 2 ‐Ag‐rGO nanocomposite was characterized by scanning electron microscopy (SEM), X‐ray diffractometer (XRD), and X‐ray photoelectron spectroscopy (XPS) to analyze its morphology, structure, and composition. It was then coated onto a glassy carbon electrode (GCE) surface to construct the TiO 2 ‐Ag‐rGO/GCE. On this modified electrode, the oxidation peak current of MEL centered at 0.65 V showed a notable improvement and was linear with MEL concentrations ranging from 0.5 to 150 μM using optimal parameters. The detection limit calculated for MEL was 15.2 nM (S/N = 3). Application of the method for the assay of MEL in the commercially available tablets form, acceptable deviation from the stated concentration and satisfactory accuracy were obtained.
No takes yet. Share an insight, caveat, or question.
Wang et al. (2025) studied this question.