Analysis reveals sensitivity of 80% for high VAF SNVs in normal tissues, suggesting improvements in low VAF mutation detection methods.
Mosaic mutations in normal tissues occur at low variant allele fractions (VAFs), complicating detection. To benchmark strategies, the SMaHT Network created a cell-line mixture (1:49) and produced ultra-deep whole-genome sequencing using short and long reads (five centers, 180-500x each). We assembled a reference of 44,008 mosaic SNVs and 2,059 Indels, cross-validation between platforms to expose limits of short-read analysis. We also partitioned the genome by mappability to examine the impact of genomic context, added a negative reference set, and accounted for culture-derived mutations. When seven institutions applied eleven algorithms to mixture data, call sets were largely discordant across tools and replicates, partly reflecting stochastic presence of low-VAF mutations in biological replicants. For >2% VAF SNVs, sensitivity and precision approached ~80% at > 300x, with little gain from additional sequencing. This work provides a comprehensive framework for reliable detection of low-VAF mutations in non-cancer tissues and a valuable resource for the community.