This empirical model predicts ion concentration effects in IS-OECTs, suggesting enhanced accuracy for biosensing applications.
Frequent monitoring of body fluids such as blood, sweat, saliva, and urine is essential for the early detection of various diseases. Ion‐selective organic electrochemical transistors (IS‐OECTs) offer a low‐cost, highly sensitive, and easily fabricated platform for detecting ion concentration changes. Their inherent flexibility and biocompatibility make them well‐suited for integration into wearable systems for continuous, point‐of‐care health monitoring. However, optimizing IS‐OECT design and circuit performance requires accurate modeling of their concentration‐dependent behavior, which is complicated by complex electrochemical interactions and charge transport dynamics. In this work, it introduces an empirical model that extends the Friedlein framework to incorporate ion concentration effects, enabling accurate prediction of steady‐state device characteristics in the presence of both target and interfering ions. Validation of this model with IS‐OECTs fabricated to detect ammonium (NH 4 ⁺) and sodium (Na⁺) ions shows an excellent agreement with experimental measurements, underscoring its reliability for electrochemical sensing applications.