Answers are grounded in this paper and cite their sources.
This analysis quantifies the effect of aspect ratio on pore size distribution in carbonate formations, suggesting new methods for improved characterization.
Pore-size distribution (PSD) is one of the basic properties for characterizing pore systems. Nuclear magnetic resonance (NMR) T2 distribution is widely used to derive PSD, typically applying a single aspect ratio (AR) value of 1.0, based on the assumption of circular pores within the model. This approach often describes the pore network with a single distribution. However, in carbonate formations, the pore system is complex and may consist of multiple pore types with different ARs, such as reference pores (interparticle pores) with a medium AR, stiff pores (moldic and vuggy pores) with an AR close to 1.0, and crack pores (microcracks and microfractures) with a low AR. Therefore, the objective of this study is to first quantify the effect of AR on T2-derived PSD, and then derive individual AR-driven PSDs for reference pores, stiff pores, and crack pores in carbonate rocks. For monomodal pore systems, pore shape is considered when deriving PSD from T2. The pore cross-section is assumed to be elliptical, and the semi-long axis (a) instead of the radius is derived from the corresponding T2 and surface relaxivity, taking the AR into account. Each T2 magnitude is then normalized to calculate the probability density function (PDF) of a-based PSD. For multimodal pore systems, the T2 distribution is first separated into individual components using trough points. Adjacent components are combined if they overlap each other and need to be processed simultaneously. Each component is then inverted separately into one or more Gaussian distributions, each representing reference pores, stiff pores, or crack pores. All possible combinations are scanned, and the differential effective medium (DEM) model and Gassmann fluid substitution are applied to calculate the reconstructed sonic slowness. This reconstructed slowness is compared with the measured slowness to identify the specific combination that best fits the sonic measurements. With this process, individual a-based PSDs are obtained for reference pores, stiff pores, and crack pores from T2 by integrating AR and sonic measurements. To validate the above methodology, synthetic T2 and sonic slowness are generated based on given volume fractions and PSDs for reference pores, stiff pores, and crack pores. By comparing the synthetic data with that from measurements, it is noted that PSD derivation from T2 can be very sensitive to AR. By decomposing the synthetic T2 into separate Gaussian distributions and assigning each to a specific pore type with the aid of synthetic sonic slowness, the new methodology can provide the correct individual PSD for each pore type, even for components with low volume fractions. The methodology is also tested with a field carbonate dataset. The reconstructed T2 closely matched the measurements, and the calculated volume fractions of reference pores, stiff pores, and crack pores generally align with those obtained from core samples, confirming that the derived individual PSDs for each pore type are reasonable and can be used in enhanced reservoir characterization, such as permeability estimation, and aid in designing mud systems with bridging agents.
No takes yet. Share an insight, caveat, or question.
Jun-tao et al. (2025) studied this question.
Synapse has enriched 8 closely related papers on similar clinical questions. Consider them for comparative context: