Answers are grounded in this paper and cite their sources.
Research reveals the static load-bearing capacity of injection bolts with MM1018 in bridge structures, highlighting its viability as a maintenance solution.
Maintenance and strengthening measures for existing steel structures play a decisive role in bridge construction. Rivets in non-weldable structures can be replaced with fitted bolts, friction grip bolts or injection bolts. For injection bolts an injection material based on a two-component system is needed, which has not been further specified yet. Material requirements were defined in the framework of the research project IGF-No. 21369 N and the suitability of the filling material MM1018 FL was confirmed. The static load- bearing capacity of non-preloaded connections with injection bolts with MM1018 was determined under different boundary conditions. The investigated curing and storage conditions were adapted to the application in bridge structures which included low curing temperatures and extreme temperature effects after curing. The practicability of MM1018 and other injection materials were exemplary tested in the course of the application of injection bolts at the steel bridge Hochstraße A in Leverkusen, Germany. Based on these theoretical and practical investigations, the filled epoxy resin MM1018, which is already a gap filling material approved by the building authorities in Germany, has proven to be a suitable injection material for connections with injection bolts.
No takes yet. Share an insight, caveat, or question.
Kunde et al. (2025) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: