October 20, 20250 citations

Noise Suppression of SAFT Ultrasound Video Using Eigen Filters

View Full Paper
CHChengyang HuangFSFRANCESCO LANZA DI SCALEA

Key Points

  • Noise suppression significantly enhances the clarity of ultrasound images, allowing better detection of internal flaws.
  • The proposed method, based on Singular Value Decomposition, effectively eliminates unwanted artifacts from ultrasound videos.
  • Utilizing a moving transducer array in railroad track inspection, the approach demonstrates strong practicality in real-world applications.
  • Results reveal that the recursive SVD filter effectively captures moving artifacts, leading to high accuracy in flaw imaging.

Abstract

In ultrasound scanning videos, noise and sub-stationary artifacts can severely impair the detection of the intended targets. This paper advances an unsupervised learning framework for noise suppression in ultrasound videos based on eigen filter concept. Specifically, the study focuses on the removal of artifacts in Synthetic Aperture Focusing Technique (SAFT) beamformed videos created by a moving transducer array in a scanning mode. The specific application is in-motion imaging of internal flaws in railroad tracks using a transducer array mounted in a Rolling Search Unit (RSU). By employing Singular Value Decomposition (SVD) analysis, an ultrasound video is decomposed into principal components through their time-space coherence/correlation. Artifacts can be eliminated by projecting out the associated principal components from the video (i.e. eigen filtering). A novel recursive algorithm with signal rectification is proposed to allow SVD filters to better capture the subtle movement of artifacts in ultrasound tomography. As opposed to the prior knowledge of a stopband in conventional SVD filters, the recursive SVD filter only removes the primary eigen mode until convergence. The proposed approach is validated through experiments using an RSU hosting a 25-element linear transducer array in defected rail sections in the laboratory and in the field. The results demonstrate a remarkable filtering ability, where artifacts (e.g. reflections at the wheel-rail interface, reverberations within the wheel, reflections from the bottom flange of the rail head) are successfully eliminated and only the internal flaws are imaged with high accuracy. This approach is applicable to any ultrasound imaging test where “loud” artifacts are present in addition to the intended targets.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Huang et al. (2025) studied this question.

synapsesocial.com/papers/68f5fcd68d54a28a75cf1f1fhttps://doi.org/10.12783/shm2025/37511