PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
October 21, 2025ACS Sensors4 citationsOpen Access

Point-of-Care Solid-Phase PCR in a Vertical Microfluidic Chip Integrated with All-Dielectric Nanostructured Metasurface for Highly Sensitive, Multiplexed Pathogen Detection

View Full Paper
ISIslam SederLBLeonid Yu. BeliaevRTRodrigo Coronel Téllez

Key Points

  • The chip demonstrates a detection limit of 10 copies/reaction, enhancing pathogen detection efficiency.
  • Utilizing a dual-heater configuration expedites thermal cycling, significantly reducing PCR reaction times.
  • The engineering of this device allows for bubble-free, gravity-assisted fluid dynamics during PCR thermocycling.
  • The platform shows potential for personalized medicine and scalable production for point-of-care diagnostics.

Abstract

Multiplexed solid-phase polymerase chain reaction (SP-PCR) has emerged as an indispensable modality for concurrent amplification of multiple genetic loci within a singular reaction vessel, facilitating efficient molecular diagnostics. Nevertheless, SP-PCR has seldom been integrated into point-of-care diagnostic devices due to several technical challenges, such as bubble formation during PCR, long reaction time, and low fluorescence signals generated from the PCR products on a solid surface. To circumvent these constraints, we engineered a microfluidic chip comprising SP-PCR and nanophotonic enhancement to enable highly sensitive, high-throughput, and cost-efficient molecular diagnostics. The chip's vertical orientation integrates preloaded reagent chambers for sequential lysis, washing, elution, and amplification, driven by a synchronized stepper motor and air vacuum, achieving robust nucleic acid purification and reverse transcription-PCR, and enabling bubble-free, gravity-assisted fluid dynamics during the PCR thermocycling. Thermal cycling is expedited through a dual-heater configuration alternating at subsecond intervals, obviating active cooling and shortening the reaction time. All-dielectric nanostructured metasurface was incorporated beneath the PCR chamber, allowing for the facile immobilization of DNA arrays to conduct SP-PCR. Taking advantage of guided-mode resonance supported by the metasurface and the SP-PCR approaches permits multiplexed detection and achieves a detection limit of 10 copies/reaction, highlighting the platform's potential for point-of-care diagnostics, personalized medicine, and high-throughput pathogen surveillance. Facile fabrication and automation emphasize scalability for mass production and deployment and collectively represent an advancement in point-of-care diagnostics.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Seder et al. (2025) studied this question.

synapsesocial.com/papers/68f6db512c99d260e8cec0d0https://doi.org/10.1021/acssensors.5c02435
Ask AI
Helpful
Bookmark
Share
View Full Paper