Model test reveals dynamic responses and horizontal displacement in reinforced soil walls under cyclic loading, suggesting vital implications for railway infrastructure.
Reinforced soil retaining walls (RSWs) for railways are key subgrade structures that bear cyclic loads from trains, and their long-term durability directly affects railway operation safety. The mechanical behavior of RSWs under cyclic loading has been extensively investigated in previous studies, primarily focusing on seismic conditions or conventional structural configurations. While these works have established fundamental understanding of load transfer mechanisms and deformation patterns, research on their responses to long-term train-induced vibrations, particularly for concrete-block-panel-wrapped RSWs, an improved structure based on traditional concrete-block-panel RSWs, remains limited. To investigate the dynamic responses of the concrete-block-panel-wrapped RSW, a model test was conducted under cyclic loading conditions where the amplitude was 30 kPa and the frequency was 10 Hz. The model size was 3.0 m in length, 1.0 m in width, and 1.8 m in height, incorporating six layers of geogrid. Each layer of geogrid was 2.0 m in length with a vertical spacing of 0.3 m or 0.15 m. The results indicate that as the number of load cycles increases, deformation, acceleration, static and dynamic stresses, and geogrid strain also increase and gradually stabilize, exhibiting only marginal increments thereafter. The maximum horizontal displacement reaches 0.08% of the wall height (H), with horizontal displacement increasing uniformly along the height of the wall. The vertical acceleration in the non-reinforced soil zone is lower than that in the reinforced soil zone. The horizontal dynamic stress acting on the back of the panel remains minimal and is uniformly distributed along the height of the wall. The maximum geogrid strain was found to be 0.88%, corresponding to a tensile stress amounting to 20.33% of its ultimate tensile strength. The predicted failure surface approximates a bilinear configuration, consisting of one line parallel to the wall face at a distance of 0.3H from the back of the soil bags and another line inclined at an angle equal to the soil’s internal friction angle (φ) relative to the horizontal plane. This study has important reference significance for the application of concrete-block-panel-wrapped RSWs in railways.
No takes yet. Share an insight, caveat, or question.
Xu et al. (2025) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: