Observational analysis shows irradiation alters electric field distribution in nLGADs, indicating significant changes in gain performance.
Low Gain Avalanche Detectors built on n-type substrate (nLGADs) have been developed by IMB-CNM to enhance the detection of low-penetrating particles, with a wide range of applications from medicine, industry to synergies with developments for high-energy physics (HEP). In this work, irradiation effects on nLGADs were investigated through proton irradiation at the CERN PS-IRRAD facility up to proton fluences of 10¹⁴\,cm⁻². Electrical characterization before and after irradiation reveals space charge sign inversion of the n-type bulk, leading to significant modifications in the depletion behavior and electric field distribution. Utilizing UV TCT and TPA-TCT measurements, the impact of irradiation on the electric fields and the gain are studied in more detail, confirming a change of sensor depletion and a reduced electric field in the gain layer. The results suggest that donor removal in nLGADs is stronger pronounced already at lower fluences compared to acceptor removal in traditional p-type LGADs. These findings provide not only first insights into the effects of irradiation on nLGADs but also contribute to the development of methods to quantify the donor removal.
No takes yet. Share an insight, caveat, or question.
Kraus et al. (2025) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: