Dynamic current balancing enhances efficiency by 3-8.6% in buck converters, highlighting its significance for data centers.
Multiphase buck converters are critical in data centers and base stations, where their efficiency and thermal performance dictate system reliability. Conventional current-sharing methods fail to equalize power losses under component mismatches, causing localized overheating and efficiency degradation. This paper introduces a dynamic current balancing strategy based on active power loss sharing. A coupled current–temperature–resistance model is developed to dynamically estimate the equivalent resistance of each phase, capturing the behavior of MOSFETs, inductors, and PCB traces. This model enables real-time, loss-based current weight adjustment to actively balance interphase losses. Experimental results demonstrate that the proposed approach improves peak efficiency by up to 3–8.6% and reduces the critical component temperature rise by 11.6 °C under typical loads, confirming its substantial value in enhancing the performance of multiphase power systems.