Analysis demonstrates improved robustness and interference suppression strategy in dual three-phase machines with predictive current control.
Sensor sampling errors and inverter dead-time effects introduce significant nonlinear disturbances into dual three-phase permanent magnet synchronous machine (DTP-PMSM) drive systems with sinusoidal excitation, leading to pronounced alternating current (AC) and direct current (DC) disturbances. These disturbances severely compromise the stability and reliability of the current control loop, ultimately degrading the overall driving accuracy of the system. To effectively address this issue, this paper proposes a novel interference suppression strategy based on bi-subspace predictive current control. Specifically, the proposed approach optimizes modulation through two-step virtual-vector-based predictive current control (VVPCC) operation to achieve disturbance decoupling. Building upon this foundation, a model-assisted discrete extended state observer (DESO) is incorporated into the fundamental subspace, whereas a discrete vector resonant controller (DVRC) with pre-distorted Tustin discretization is applied to the secondary subspace. Modeling analysis and experimental results demonstrate that, compared with the classical VVPCC method, the proposed bi-subspace VVPCC method has good steady-state performance and enhanced robustness in the presence of disturbances.
No takes yet. Share an insight, caveat, or question.
Yu et al. (2025) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: