Systematic review and meta-analysis shows comparable outcomes and reduced artifacts for CFR-PEEK implants in spinal tumors, with potential mortality benefits.
BACKGROUND Surgical treatment is a crucial component in the management of spinal tumors. Conventionally, titanium has been the implant material of choice. However, they cause significant imaging artifacts, affecting radiotherapy planning and tumor surveillance. Carbon fiber-reinforced polyetheretherketone (CFR-PEEK) implants have been gaining traction, as they minimize interference on imaging, improve radiotherapy dosing, and reduce radiation scattering. We conducted a systematic review and meta-analysis to evaluate the complications, outcomes, and impact on radiotherapy after surgical fixation with CFR-PEEK implants, and compare them to titanium implants for patients with spinal tumors. METHODS PubMed, Embase, Cochrane, Web of Science, and Scopus databases were searched to March 2025. Primary outcomes were hardware failure, deep surgical infection, and reoperation for hardware-related complications or deep surgical infection. Secondary outcomes were local recurrence, mortality, length of hospital stay, and artifact volume. RESULTS 34 studies were included, of which five were included in the comparative meta-analysis. Compared to the titanium group, the CFR-PEEK group had similar rates of hardware failure (1.2% vs 0.7%, OR=1.73 [0.40-7.60], p=0.47) and deep surgical infection (2.1% vs 1.5%, OR=1.62 [0.49-5.38], p=0.43). Local recurrence (8.8% vs 13.0%, OR=0.58 [0.29-1.18], p=0.13) and mortality rates (36.0% vs 50.3%, OR=0.52 [0.25-1.09], p=0.08) were non-significantly lower in the CFR-PEEK group. Length of stay (6.72 vs 10.45 days, MD=-3.15 [-9.65, -3.34], p=0.34) was comparable between the two groups. CFR-PEEK implants generated significantly lower volume of imaging artifacts compared to titanium implants (SMD=−1.36 [−1.83, −0.90], p<0.001). Meta-analysis of pooled proportions including non-comparative studies were also reported. CONCLUSIONS Whilst having similar rates of implant-related complications compared to titanium implants, CFR-PEEK implants significantly reduce artifact generation and may lead to lower recurrence and mortality rates due to improved radiotherapy planning and delivery. Prospective studies and randomized trials will further establish the evidence for CFR-PEEK implants in spine tumor surgery.
No takes yet. Share an insight, caveat, or question.
Zhang et al. (2025) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: