Fan Coil Unit Influence on Thermal Comfort in Waiting Areas of Energy-Efficient Office Buildings

View Full Paper
MFMałgorzata Fedorczak-CisakAKAlicja Kowalska-KoczwaraABAleksandra Buda-Chowaniec

Key Points

  • Occupant feedback reported discomfort from strong air movement near the Fan Coil Unit, indicating the need for better control strategies.
  • Despite efficient temperature increase, localized discomfort persisted due to the Fan Coil Unit's operation during heating cycles.
  • Analysis of microclimate parameters and occupant feedback revealed potential mismatches between predicted comfort indices and real perceptions.
  • Findings support the optimization of HVAC control in semi-transient waiting areas of nearly zero-energy buildings.

Abstract

Ensuring thermal comfort in waiting areas is essential for visitor satisfaction and well-being. In the context of nearly zero-energy buildings (nZEBs), these spaces—typically characterized by short-term occupancy, transient user behavior, and the need for rapid temperature adjustment—pose specific challenges for HVAC control in balancing comfort and energy demand. This study investigates the influence of a ceiling-mounted fan coil unit (FCU) operating in heating mode on thermal comfort conditions in an nZEB office waiting area. Measurements were conducted at multiple points within the space to assess microclimate parameters, followed by the calculation of the predicted mean vote (PMV) and predicted percentage of dissatisfied (PPD) indices, supported by occupant feedback collected through short interviews. The results showed that although the FCU effectively increased the average temperature, its intermittent operation and localized air jets during the heating phase caused temporary discomfort near the unit. Occupant feedback confirmed sensations of discomfort due to strong air movement during FCU operation but indicated slightly higher overall dissatisfaction and smaller variability compared to model-based PPD values, reflecting the averaging effect of occupant perception over time. These findings highlight the need for optimized FCU control strategies in waiting areas, such as operating at reduced fan speeds and preheating the heat exchanger, to enhance occupant comfort. This study contributes to improving HVAC control concepts for semi-transient spaces in nZEBs.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Fedorczak-Cisak et al. (2025) studied this question.

synapsesocial.com/papers/692b94601d383f2b2a37923bhttps://doi.org/10.3390/en18236187
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Fan Coil Unit Influence on Thermal Comfort in Waiting Areas of Energy-Efficient Office Buildings2025
  2. 2Balancing Cooling and Comfort: Lessons from Fan Coil Units in Estonia2026
  3. 3Study on the Thermal Comfort in Office Buildings adopting Low Velocity Air Circulation and Displacement Ventilation Systems2026
  4. 4Thermal Comfort Analysis in Dormitory Room by Combined MVHR-Fan Coil2025 · 3 citations
  5. 5Field investigation of the impact of different terminal devices on thermal comfort and ventilation uniformity2026